ENERGY SMART COMMUNITIES INITIATIVE Knowledge Sharing Platform
Home ESCI-KSP Smart Buildings Low Energy Building Network SB-1.3 Low Energy Building Programs, Initiatives, and Partnerships Phyathai2 International Hospital – Energy Conservation in a “green hospital”
:::

Phyathai2 International Hospital – Energy Conservation in a “green hospital”

Posted:10/22/2015 Last Modified:07/16/2025 Views:169
Energy Conservation in a “green hospital”

Managing Organization:

Since 2011, the management has appointed to form a responsible working group as known as the Energy Committees to overlook the energy conservation campaign. The Energy Committees is responsible for deciding on strategic planning and implementation of activity to meet the set goal. The plans and progress should be reviewed and improved yearly. Presently, Dr.Anantasak Apairatana, Hospital Managing Director is acting the chief of the Energy Committees; the committees are comprised of executive directors and managers from all departments, while Mr.Att Thongtang, CEO of Corporate Group is acting as honorary advisor.

Project Description:

In energy conservation investment projects, Phyathai 2 concentrate on high power consumption equipment, and found that the air-conditioning and lighting are the highest ratio of all major components in facility. That brought about the replacement of water-cooled chiller and LED light tubes, started from 2011, and continue the investment in more efficiency technology up until the present. In term of these investments, besides the saving it’ll gain, another major focus point is on the reduction of the environmental impact.

Energy Conservation Activity Conservation per year Invest (THB) Payback Period (year)
Electricity Fuel
(kWh) (THB) CO2 Reduced (TON) (MJ) (THB) CO2 Reduced (TON)
Year: 2011 Measures from non-investment                
Adjust to optimized chilled water temperature. 143,664 465,471 104.4          
Measures from investment                
Replace Fluorescent light bulbs from 36W (T8) to 28 W (T5) 862 set. 120.818 391,450 87.8       821,715 0.85
Replace Fluorescent light bulbs from 28W (T8) to 15W(T5)1,564 set 178.108 577,070 129.4      
Replace Halogen 50 W. toLED 3W. 175,267 567,867 127.3       415,695 0.73
Total for 2011 617,857 2,001,858 449       1,237,410 0.62
Year: 2012 Measures from non-investment                
Reducing electric power heater use to soft towel box for retain heat 12,045 46,735 8.8          
Reduce time, process and energy in preparing meeting room. 53,541 207,739 38.9          
Installed Timer control Air-Cond Conveyor room. 60,917 236,358 44.3          
Adjust to optimized chilled set point. 143,664 557.416 104.4          
Measures from investment             6,000,000 2.57
Replacement to High-Eff. Chiller water cool 602,434 2,337,444 437.7       897,730 0.83
Installed VSD for HVAC plant. 277,648 1,077,274            
Total for 2012 1,150,249 4,462,966 634       6,897,730 1.55
Year: 2013 Measures from non-investment                
Reducing electric power heater use and using STERILE water for prepare infant milk 5,076 19,694 3.7          
Measures from investment                
Reusing RO Reject water         46,165   174,196 3.77
Contest and promotion of energy conservation.             1.000,204  
Installed VSD for AHU(OPD Area) 38,106 137,181 27.7       323,400 2.19
Combined chiller plant and use high efficiency chiller 1,285,756 4,988,734 934.1       12,700,000 2.55
Replaced Flu. lamp 36 W to LED tube 300,188 1,164,728 218.1       2,240,600 1.92
Installed dimmer ballast with motion sensor for Fluorescent lamp 36 W 245.465 952,404 178.3       1,000,000 1.05
Installation of lighting for around the building by 1 kW solar power 2,350.60 9,120 1.7       650,000 19.8
Installed Solar collector system 18,697 67.309 13.6 206,478 74,006 13 467,000 3.19
Installed electronics Thermostat 11,753 45,601 8.5       50,000 1.1
Installed "LOSSNAY" 21,310 82.683 15.5       216,000 2.61
Total for 2013 1,928,702 7,467,454 1,401 206,478 74,006 13 18,821,400 2.48

Savings Narrative:

During the past three years, since the energy conservation campaign has started, the administration has allocated funds of around 26.96 MB budget to develop and improve all three important aspects, People ware, Hardware and System ware, to best achieve the results. Investment projects, such as the applications of efficiency and appropriate technology have been implemented; i.e. the combined of Chiller Plants that used in both buildings, a replacement of the more efficient water-cooled chillers, installation of Chiller Plant Manager System (CPMS), Variable Speed Drive (VSD) for all the motors in the HVAC system of both buildings. Moreover, even in some other systems, such as lighting; replacement of T8 with the LED fluorescent tubes and also installed the motion sensor in some areas, the use of renewable energy such as solar-collector to produce hot water with an average payback period of only 2.14 years. The result of energy management proved to help generate the saving of up to 12.57 million THB.

Managing Organization:
Phyathai2 International Hospital Energy Committee
Electricity Displaced:
1.9 million KWh per year
Building Type:
Commercial (single-tenant)
Building Size (m2):
59,638
Building Energy Usage (KWh/yr/m2):
199.7
Carbon Emissions Offset (Metric Tons CO2 per year):
1400